* Item may not be available at selected location *

BiPAP autoSV with Encore Pro SmartCard

HomeCatalogBilevel PAPBiPAP autoSV with Encore Pro SmartCard

The BiPAP autoSV sleep therapy system is specifically designed to be the best choice for managing complicated sleep-disordered breathing patients. It combines a number of technologies to recognize and...

Product Order Request

Product Unavailable!

Please select a different set of options

  • In Stock

Details & Specs for BiPAP autoSV with Encore Pro SmartCard

The BiPAP autoSV sleep therapy system is specifically designed to be the best choice for managing complicated sleep-disordered breathing patients. It combines a number of technologies to recognize and react to changing pressure needs, and it's clinically proven to treat obstructive, central and complex apneas and hypopneas, along with periodic breathing. 

Obstructive Sleep Apnea (OSA)
OSA is the absence of airflow due to an occlusion in the upper airway that lasts at least 10 seconds in spite of continual effort to breathe. Severity is measured by the Apnea/Hypopnea Index (AHI) - the number of episodes per hour of sleep.

Central Sleep Apnea
Central Sleep Apnea is a pattern of breathing characterized by a normal deep inspiratory cycle interchanged with complete cessation of breathing. It is typically caused by problems with how the brain controls breathing rather than an occlusion of the airway.

Complex Sleep Apnea
Complex sleep apnea is a condition that occurs when a patient is identified as having OSA, but with the application of Continuous Positive Airway Pressure (CPAP) to eliminate the OSA, the patient develops Central Sleep Apnea. The cause of complex sleep apnea is not known at this time.

Periodic Breathing
Periodic breathing is defined as alternating periods of hyperventilation with waxing/waning tidal volume and periods of central hypopneas or apneas. There are many forms of periodic breathing, one of which is Cheyne-Stokes Respiration (CSR). CSR is characterized by a cyclic pattern of waxing and waning during periods of apnea, and deep, rapid breathing.

Pressure range IPAP max: 4 cm H2O to 30 cm H2O
Pressure range IPAP min: 4 cm H2O to 30 cm H2O
Pressure range EPAP: 4 cm H2O to 25 cm H2O
Breath rate AUTO, 4~30 BPM, Off
Dimensions 9.75" (l) x 6.63" (w) x 4.40" (h)
Weight < 4 lbs.
FILTERS Reusable pollen and optional ultra-fine
Device set-up On-board keypad and SmartCard
Data storage capacity 6 months @ 3 usage sessions/day; 7 days in-depth data analysis
DATA STORAGE CONTENT Date, time, duration at pressure
DATA STORAGE CONTENT Short-term detailed events, long-term trends
Altitude compensation Automatic
Electrical Requirements 100~240 VAC
Electrical Requirements 12 VDC (when operated with external DC power adapter accessory)
DC power Direct-connect cord
Warranty 2 years

Customer Reviews

There are no reviews written for this product at the time. Maybe you can be the first!